IMCA has reported an incident in which a CCTV camera (weighing 5.8kg) fell approximately 3 meters down a crane pedestal ladder before being arrested by its data cable, which prevented it falling on to the main deck.
A 50Te crane was tasked with the recovery of subsea equipment. During this operation the crane was started and rotated outboard portside in order to deploy the hook to seabed. This 50Te crane was designed with a fixed access ladder, complete with a “backscratcher” from the main deck to the first level walkway on the crane pedestal, a height of 7.4 meters. From this walkway, there are three additional ladders fixed to the crane, two of which are for maintenance purposes and the other leads to the crane operators control cabin. These additional ladders rotate with the crane as it is slews in the required direction. As the crane was rotated, one of these ladders caught the CCTV camera that had been secured to the walkway following maintenance during the previous shift, pulling it approximately 1 meter to the access hatch, where it fell before being arrested by the data cable.
Findings
- The CCTV camera had been removed from its mountings the day before the incident to allow investigation of reports that it was not working properly;
- The faulty camera could not be repaired at the time and as such, was secured to the crane walkway using tiewraps;
- The access hatch located on the walkway was left in an open position while crane operations were ongoing.This is common practice and is done to allow suitable access/ogress to and from the crane in the event of a crane breakdown or if a rescue operation is required. The crane design prevents the hatch from being opened when one of three ladders are positioned over it, restricting access/egress;
- The work conducted on the camera and the status in which it was left was not communicated to the crane operator or the project construction crew at shift handover/TBT. The on-shift crane operator was not made aware that work had been conducted on the crane pedestal and did not identify the CCTV camera during the pre-use inspection;
- The CCTV repair was considered to be covered under a company “routine duty for work on low voltage systems”;
- The correct process for approving “routine duties” had not been followed which resulted in this particular routine duty being absent from the appropriate register of such duties kept on the vessel.
Lessons learnt, actions taken, and conclusions:
- There was a lack of awareness and risk perception of the hazard presented by the rotating ladders;
- A more thorough pre-use inspection of the walkway would have discovered the potential dropped object;
- Improved communication – particularly at shift handover – between all parties would have raised awareness of the operation;
- Had this operation been conducted under a permit to work (PTW) or the correct process followed for routine duty activities, awareness of the operation would have been greater. It is important to highlight that control measures had been implemented by those conducting the work to ensure safe execution of the task and that these were removed when the worksite had been deemed safe;
- Personnel were clear of the crane pedestal at the time of the incident due to the task being conducted and member’s procedures for controlling access to the crane when in use. Our member reviewed processes for controlling access to ensure they were robust in protecting personnel from injury. The safe system of work for all ladders on worksites, both permanent and temporary was reviewed, with consideration being given to suitability of design, position and access/egress.
Source & Image credit: IMCA Safety Flash