The Nautical Institute describes an incident where a mass of tiny fish was found inside a sea chest, leaving the strainer completely choked from the suction side.
The incident
An oil tanker was discharging at an Asian oil terminal. Simultaneously, the vessel was being inspected by a vetting inspector and the owner’s superintendent was also attending. The inert gas (IG) plant was in operation.
About four hours into the discharge, the C/E was informed that the seawater low pressure alarm had been activated.
He went to the engine room and observed that all the sea water pumps were showing inadequate discharge pressure.
At the time, the high sea suction was in use, and even though it was well under water, the C/E instructed the duty engineer to change over to the low sea suction in order to improve the head.
Immediately, the pump suction and discharge pressures became normal.
After monitoring the system for some time, the C/E left for his cabin. After a few more hours, the problem recurred and the C/E again returned to find all seawater pumps had developed vacuum condition on the suction side and were showing very low discharge pressures.
It was immediately suspected that the strainers inside the sea suction chests were clogged. However, with the cargo pumps and IG plant operating at full capacity, it was decided to use both the high and low sea suctions together to avoid stoppage of any of the seawater pumps.
It was not possible to open up any of the sea chests to clean the strainer without halting the discharge, with attendant commercial implications.
The Master and superintendent were informed of the serious situation, when, by chance, the terminal announced a temporary stop in cargo operation.
Until this stoppage time, the engine room had spent a few hours with the pumps struggling to develop adequate water flow.
In the middle of this crisis, a class surveyor was scheduled to attend for annual survey. On arrival, he declared his intention of testing the operation of the deck foam monitor with both fire and service pumps, which was quite a tough task under the circumstances.
With great trepidation, the engineers were able to adjust the pump suction and discharge valves to satisfactorily demonstrate the operation of the deck foam monitor.
Probable cause
Soon after the departure of the class surveyor, cargo operations were halted at the terminal’s request and with the IG scrubber and condenser sea water pumps stopped, and auxiliaries under control, the low sea chest was opened up for inspection.
A mass of tiny fish was found inside, and when the strainer was extracted, it was found to be completely choked from the suction side.
After non-stop work by the crew, the suction was completely cleaned out, and the strainer replaced after the mesh was cleared.
After the sea chest was boxed up, it was put in use and all seawater pumps were tested and found to be developing normal pressures.
The high sea suction was also found to be choked with fish, and was similarly cleared and boxed up, by which time cargo discharge was resumed, with terminal instructions for continuous discharge until completion.
Unfortunately, just four hours after resuming cargo discharge, seawater pressure again became low, forcing the simultaneous use of both sea suctions.
The Master and superintendent were regularly updated of the situation, when, without prior intimation, port state inspectors boarded the ship. The mess near the sea suctions was quickly cleaned up, and the vessel passed the inspection creditably.
Just after the port state inspection, and towards the end of cargo discharge, abnormally high temperatures were observed in the steam condenser shell and condensate lines, calling for urgent corrective actions.
Discharging was finally completed later that night.
The engine room crew once again opened, cleaned and boxed up the sea suctions (again filled with tiny fish) and the ship sailed from the terminal without any delay.
Preventive actions
The fleet was advised to use high sea chest in ports, as this is generally located close to several overboard discharges; e.g. ballast, condenser sea water, fire and general service (GS), and IG scrubber pumps.
The turbulence created in the vicinity of these overboard discharges may help prevent fish being drawn towards the high sea suction.
It was also suggested that regular injection of steam into sea chests might assist in keeping the strainers clear of unwanted fishes and other organisms.
Lessons learned
- Sea chests should not be used without filter strainers in place and should be monitored regularly.
- Detailed procedures for cleaning seawater strainers should be present, which may include back-flushing or regular changing and cleaning duplex strainers as appropriate.
- The service sea chest, as well as filters and coolers, should be regularly inspected and cleaned.
- The pressure on pumps and filters should be monitored and crew must be prepared to respond quickly when reduced performance is observed.
- All tools and equipment for opening the sea chest and cleaning the strainer should be prepared and ready for usage.
I think, Having a second strainer as spare part would be a good help in this situation!
Risk Assessment sea chest cleaning should be applied on board