A Liquified Petroleum Gas (LPG) vessel was loading LPG that wasat a higher temperature than desired for transit. In order to cool the LPG cargo, the gas was re-liquefied to a lower temperature by using the vessel’s boil off system. The gas was first directed to a compressor, compressed to a higher pressure, and then condensed back to a liquid at a lower temperature. From the condenser it flowed through an expansion valve and back to the tank. It was reported that while this system was operating, the piping near the expansion valve began constricting flow due to freezing hydrates. This then caused an increase in system pressure from the expansion valve back via the condenser and to the outlet of the compressor.
It appears probable that the drains at a sample point were left cracked open, or just leaking, to allow hydrates to escape. In any event, significant accumulations of ice were noted in the bilge areas below the same sample point for two of the three liquid line drains. A hazardous flammable atmosphere was therefore allowed to develop and a spark of unknown origin ignited a fire near the condenser. It was extinguished quickly by a crew member using handheld dry chemical extinguishers.
The investigation also identified other concerns, such as:
- An emergency system left in the manual mode prevented remote activation;
- Senior organisational personnel for the operator and facility were not informed of the hydrate situations;
- Procedures for taking actions when gas alarms sounded were not followed; and
- Gas detection devices were not properly calibrated.
Lessons learned |
It is likely that unsafe cargo handling procedures associated with manual draining of hydrates from the drain line on the outlet of re-liquefaction condensers directly contributed to this casualty. Although not every scenario that involves decision making of officers and crewmembers can be documented, it is reasonable to expect that those procedures that are part of day-to-day operations are documented in the SMS. In this case, removal of hydrates was not a documented procedure. Routine and frequent training should be given to shipboard officers and crew based on documented procedures; in the case of LPG vessels it should cover such topics as the safety risk of releasing LPG in open and enclosed spaces. Proper methods to acknowledge and investigate gas detection alarms regardless of location (including making proper notifications to responsible parties). |
Source: Nautical Institute
The Mariners’ Alerting and Reporting Scheme (MARS) is primarily a confidential reporting system run by The Nautical Institute to allow full reporting of accidents (and near misses) without fear of identification or litigation. As a free service to the industry, MARS reports also regularly comprise alerts condensed from official industry sources, so that issues resulting from recent incidents can be efficiently relayed to the mariner on board. With access to the internet from vessels becoming more affordable, the MARS database is a valuable risk assessment, work planning, loss prevention tool and training aid for crew and management. MARS reports are held in a publicly-accessible database and can be accessed by clicking on the link below: Contact the Editor of MARS at[email protected] |
Above Mars Report is edited fromUS Coast Guard Safety Alert 3-15