IMCA has reported a near miss incident in which a divers’ umbilical ruptured. A dive system technician was doing routine pressure testing (following company planned maintenance schedules) on one of the divers’ umbilical.
As the umbilical was being brought up to testing pressure, the distinct sound of an air leak was heard. The dive technician stopped further pressurization and went to investigate the air leak. Before the final test pressure could be reached the umbilical breathing hose ruptured at about 14 Bar pressure.
Findings
- There was damage to the outer coating of the divers breathing hose at the area of the leak;
- The actual hose had some mechanical damage that may have contributed to the cause of the burst during the pressure test;
- The damage on the breathing hose was 80m from the diver’s end. Since the damage was found 80 meters from the diver’s end, the damage is likely to have occurred somewhere on the diving platform;
- The outer coating of the pneumo hose was damaged at the same location;
- The umbilical was part of a diving system that had just returned from a project and was undergoing a pressure test as per company procedures.
Lessons Learned
Pressure testing should be carried out in a clearly marked designated area, and that all nearby personnel should to be informed when a pressure test is to be carried out. Personnel conducting the test should be using the correct personal protective equipment (PPE). There should be close visual inspection of the umbilical for surface damage before the pressure testing starts – if any area is found to be damaged, the adjacent area should be cordoned off whilst pressure testing.
IMCA reiterates the importance of safe umbilical handling and making efforts to keep the divers’ umbilical
safe from any damage even on the diving platform at all times.